{"id":24990,"date":"2024-11-19T07:30:20","date_gmt":"2024-11-19T07:30:20","guid":{"rendered":"https:\/\/www.hanitalenses.com\/?post_type=publication&p=24990"},"modified":"2024-12-29T09:19:33","modified_gmt":"2024-12-29T09:19:33","slug":"short-term-visual-outcomes-after-bilateral-pentafocal-intraocular-lens-implantation","status":"publish","type":"publication","link":"https:\/\/www.hanitalenses.com\/pt-br\/publication\/short-term-visual-outcomes-after-bilateral-pentafocal-intraocular-lens-implantation\/","title":{"rendered":"Short-Term Visual Outcomes After Bilateral Pentafocal Intraocular Lens Implantation. A Pilot Study"},"content":{"rendered":"
To evaluate short-term refractive and visual behavior after implantation of a new pentafocal
\nintraocular lens to manage presbyopia in otherwise healthy patients.<\/p>\n
A retrospective observational study was conducted, in which the postoperative outcome
\nwas evaluated three months after surgery. Patients in whom the Hanita Intensity SL intraocular lens was
\nimplanted in immediate sequential bilateral surgery were assessed. Medical records were reviewed to
\ncollect information on corrected and uncorrected vision, subjective refraction, and defocus curves with
\ncorrection.<\/p>\n
Twenty eyes belonging to 10 patients were included. There was a preference for the female sex
\n(70%). The 100% of patients achieved vision equal to or better than 20\/25 in near and far vision; 100%
\nof the patients achieved a vision equal to or better than 20\/40 in intermediate vision. The defocus curve
\nshowed excellent visual performance in the vergences from infinity to approximately 33cm, with functional
\nvision at all distances; 100% of the patients reported being free of glasses for all distances.<\/p>\n
Hanita Intensity SL intraocular lens implantation is a safe and effective technique for managing
\npresbyopia. In well-selected patients, it can provide a high proportion of independence in spectacle wear
\nfor distances up to approximately 33cm.<\/p>\n","protected":false},"excerpt":{"rendered":"
This study aimed to assess the short-term refractive and visual outcomes following the implantation of the Hanita Intensity SL pentafocal intraocular lens (IOL) in patients with presbyopia. In a retrospective observational review, 20 eyes from 10 patients (70% female) who underwent immediate sequential bilateral surgery were evaluated over three months. Results showed that 100% of patients achieved visual acuity of 20\/25 or better for both near and far distances, and 20\/40 or better for intermediate distances. The defocus curve indicated excellent visual performance from infinity to approximately 33 cm, allowing functional vision at all distances. Additionally, all patients reported complete independence from glasses. These findings suggest that the Hanita Intensity SL IOL is a safe and effective option for achieving spectacle independence in presbyopic patients.<\/p>\n","protected":false},"featured_media":25009,"template":"","yoast_head":"\n